• Vsg1-12 Vacuum Circuit Breaker, Indoor Type
  • Vsg1-12 Vacuum Circuit Breaker, Indoor Type
  • Vsg1-12 Vacuum Circuit Breaker, Indoor Type
  • Vsg1-12 Vacuum Circuit Breaker, Indoor Type

Vsg1-12 Vacuum Circuit Breaker, Indoor Type

Breaking Capacity: High Voltage Circuit Breakers
Operation: Electric Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: Vacuum
Installation: Withdrawable
Structure: Vcb
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
VSG1-12
Poles Number
3 Pole
Type
Circuit Breaker
Function
Short-Circuit
Certification
ISO9001-2000, CCC
Transport Package
Plywood
Trademark
Talent
Origin
China
HS Code
8535210000
Production Capacity
5000 Pieces/Year

Product Description

VSG1-12 Vacuum Circuit Breaker, Indoor type
1.General
1.1 Ratings:rated voltage 12KV, rated current 630A~1250A, AC50HZ
1.2 Application: for the control and protection of substation and equipments; making and breaking short-circuit current under various operating status of electric network.
1.3 Standard: IEC62271-100
2. Type and Interpretation
3. Working condition
3.1 Ambient air temperature: -25~40ºC
3.2 Altitude:≤2000m
3.3 No operating in such as subject to dust, dirt, smog, corrosive/flammable gas, vapor and salt pollution.
3.4 Humidity: Daily average value ≤95%
                      Monthly average value ≤90%
3.5 Water vapor pressure: Daily average value ≤2.2Kpa
3.6 The external shocking and earthquake could be neglected.
3.7 The amplitude of electromagnetic interference in the secondary system ≤1.6KV
Note: Customized products are available on your requirements.
4.Main technical parameter
Item Unit Data
Rated voltage KV 12
Rated              1min power frequency withstand voltage(vacuum open contacts)
insulation         Lightening impulse withstand voltage(vacuum open contacts)
level
KV
KV
42
75
Rated frequency HZ 50
Rated current A 630,1250
Rated short-time withstan current KA 16,20,25, 31.5
Rated withstand current(peak) KA 40,50,63
Rated short-circuit breaking current KA 16,20,25
Rated short-circuit making current KA 40,50,63
Rated duration of short-circuit S 4
Rated operating sequence   O-0.3S-CO-180S-CO
Mechanical life   M2 class(30000times)
Rated voltage of operating power   AC 220/DC 220
Full breaking time   ≤70
Electrical life   E2 class
5.Overall and Installation Dimension
5.1 overall and installation dimension of fixed type circuit breaker

Vsg1-12 Vacuum Circuit Breaker, Indoor Type

Alternative parameters table1
Rated voltage Rated current Rated short-circuit P A B D
KV KA breaking current, KA mm mm mm mm
12 630,1250 20,25,31.5 150 20 410 450
Alternative parameters table2                           
Rated voltage Rated current Rated short-circuit P A B C D W
KV KA Breaking current, kA mm mm mm mm mm mm
  630 20,25           35
12 630,1250 20,25,31.5,40 150 494 456 490 502 49
 
Series Number Symbol Name Remark
1 YQ-Y9 Indirect over-current release Chosen  element
2 Y1-Y4 Rectifier element  
3 KO Inner mechanism anti-jumping relay  
4 P Handle operation mechanism  
5 Y1 blocking eletromagnet Chosen element
6 HQ Closing release  
7 TQ Breaking release  
8 M Energy storing engine  
9 S9 assistant switch used at operation position  
10 S8 assistant switch used, at test positin Chosen element
11 S2 Blocking electromagnet assistant switch  
12 S1 Inching switch for energy storing  
13 QF assistant switch of breaker contact  

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
85
Year of Establishment
1996-01-16