• Switchgear Gjs6-12 (F)
  • Switchgear Gjs6-12 (F)
  • Switchgear Gjs6-12 (F)
  • Switchgear Gjs6-12 (F)
  • Switchgear Gjs6-12 (F)

Switchgear Gjs6-12 (F)

Type: Power
Structure: Fixed Board
Certification: ISO9001:2000
Form: Partly-welded Type
Operation Voltage: 12kv
Size: 350mm
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
GJS6-12(F)
Application Range
Industrial, Commercial, Utility
Shell Material
Steel Plate
Shell Protection Grade
IP67
Brand
Talent
Transport Package
No Packing
Trademark
Talent
Origin
China
HS Code
853720900
Production Capacity
5000 Pieces/Year

Product Description

Module F
Standard Configuration and features

1.630A busbar
2.Three-position load switch, mechanical linkage of earthing switch between fuse head and fuse end

3.Three-position single spring operating mechanism, there are two independent load switches and switching shafts
4.Position indication of Load switch and earthing switch
5.Fuse tube
6.Horizontal placement of fuses
7. Fuse trip indication
8.Outgoing bushing arranged horizontally located in front, 200A 200series plug-in bushing
9.Indicating bushing live with capacitive voltage indicator

10.For all the switch function, the padlock device is added on the panel for convenient
11.SF6 Gas pressure gauge (There is only one in each of the SF6 gas box)

12. Earthing busbar
13.Fuse parameters for transformer protection: 12KV, max125A Fuse, 24kv,max63A Fuse

14.Earthing switch is interlocked with the front panel of cable room
Optional configuration and features
1.The reserved busbar extension
2.External busbar
3.Motor for Load Switch Operation 24V/48V DC  110V/220V DC/AC

4.Parallel trip coil 24V/48V DC 110V/220V DC/AC
5.Parallel closing coil 24V/48V DC 110V/220V DC/AC
6.Measuring ring current transformer and ampere-meter
7.Calculating ring current transformer and watt-hour meter
8.Live incoming earth blocking device (Blocking earthing switch when bushing is live) AC/DC 110V/220V
9.Auxiliary contact: Load switch position 2NO+2NC,Earthing switch position 2NO+2NC,Fuse blow 1NO,Pressure gauge with signal 1NO,Arc extinguisher with signal contacts 1NO

10.Secondary device can be installed in: Secondary chamber on top of switchgear,Low voltage box on the top of switchgear
Producing department
Switchgear Gjs6-12 (F) Switchgear Gjs6-12 (F) Switchgear Gjs6-12 (F)
Test department
Switchgear Gjs6-12 (F) Switchgear Gjs6-12 (F) Switchgear Gjs6-12 (F)


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
85
Year of Establishment
1996-01-16