(SG(B)-17) Class H Cast-Resin Amorphous Dry-Type Transformer

Application: Power
Phase: Three
Core: Core-type Transformer
Cooling Method: Dry-type Transformer
Winding Type: Two-winding Transformer
Certification: ISO9001
Samples:
US$ 5000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
SG(B)-17
Usage
Power Transformer, Distribution Transformer
Frequency Characteristics
Power Frequency
Shape of Core
EC
Brand
Talent
Transport Package
Plywood Box
Trademark
Talent
Origin
China
HS Code
854710000
Production Capacity
2000 Pieces/Year

Product Description

SG(B)-17 Class H  Dry-type Transformer
Normal operation condition 
Altitude      < 1000 m Indoor
Max. Ambinet temperature     +40ºC
Max. Daily average temperature       + 30ºC
Max. annual average temperature    +20ºC
Min. temperature  -5ºC
Supply transformers operate under special conditions according to customer requirements.
Features 
1. The core is made of cold rolled grained high-oriented silicon steel sheets  that thickness ≤0.3mm with 45 degree mitred joints. The surface is coated with special resin for moisture and rust proof.
2. Normally the LV winding materials is copper foil cylinder type excepet for small capacity transformers which LV winding materials is copper wire; The HV winding structure is multi-layer cylinder type that has good ampere-turn balance, low leakage flux, high mechanical strength and strong short-circuit withstand capability.
3. By installing the low noise fans that controled by the temperature control device,the operation capacity of the transformer can be increased by 40%.
4. The temperature device which sensers buried in LV winding can control the fans or send alarm & trip signals to protect the transformer.
5. The transformer can be installed in a enclosure which protetion class is IP20 or IP23, the enclosure can prevent small animals coming inside the transformer to avoid short circuit, and also safeguard the personal safety.
6. Sc(b)9      No-load losses Equal To Standard Value In GB/T10228-2008
                    No-load losses Equal To Tagged Value In GB/T10228-2008
    Sc(b)10   No-load losses Decrease By 10% Compared with Standard Value In GB/T10228-2008
                    No-load losses Decrease By 5% Compared with Tagged Value  In GB/T10228-2008
Technical Data
Rated
capacity
(KVA)
Rated voltage Coupling
group label
KW
No-load
loss
Load loss(W) Idling
current
(%)
Short-circuit
impedance(%)
High
voltage
Tapping(%) Low
voltage
100ºC
(B)
120ºC
(F)
145ºC
(H)
30 6
6.3
6.6
10
10.5
11
±5
±2×2.5
0.4 Dyn11 70 670 710 700 1.6 4
50 90 940 1000 1070 1.4
80 120 1200 1380 1480 1.3
100 130 1480 1570 1600 1.2
125 150 1740 1850 1980 1.1
160 170 2000 2130 2250 1.1
200 200 2370 2530 2710 1.0
250 230 2590 2760 2960 1.0
315 280 3270 3470 3730 0.9
400 310 3760 3900 4280 0.8
500 360 4690 4880 5230 0.8
630 420 5530 5880 6290 0.7
630 410 5610 5060 6400 0.7 6
800 480 6550 6960 7460 0.7
1000 550 7650 8130 8760 0.6
1250 650 9100 9690 10370 0.6
1600 760 11050 11730 12580 0.6
2000 1000 13600 14450 15560 0.5
2500 1200 16150 17170 18450 0.6
1600 760 12280 12960 18900 0.6 8
2000 1000 15020 15960 17110 0.5
2500 1200 17760 18890 20290 0.5
Note: The physical dimension in the manual is only provided for design reference, and the fimal dimension shall be based on the actual outline drawing.
(SG(B)-17) Class H Cast-Resin Amorphous Dry-Type Transformer

 

Send your message to this supplier