110KV Level Three-phase On-load Tap-changing Electric Power Transformer
Usage enviroment conditon 
1. Divice type: outdoor
2. Enviroment temperature: -30ºC ~ +40ºC
3. Altitude: ≤1000m (> 1000 m, need to modify temperature rise)
4. Relative temperature: ≤ 90% (20ºC)
5. Installation area: Area with no corrosive gas and abvious fouling etc.
TECHNICAL DATA
6300KVA~180000KVA three-phase two windings NLTC power transformer
Rated capacity
(KVA)
Voltage combination and range of tapping  Vector
group
No-load loss kw(9) Load loss kw(9) No-load current Short circuit
impedance
High voltage Low voltage
6300

110±2×2.5%
115±2×2.5%
121±2×2.5%


 
6.3
6.6
10.5
YNd11 7.40 35.0 0.62 10.5
8000 8.90 42.0 0.62
10000 10.5 50.0 0.58
12500 12.4 59.0 0.58
16000 15.0 73.0 0.54
20000 17.6 88.0 0.54
25000 20.8 104 0.50
31500 24.6 123 0.48
40000 29.4 148 0.45
50000 35.2 175 0.42
63000 41.6 208 0.38
75000 13.8
15.75
18
21
47.2 236 0.33 12~14
90000 54.4 272 0.30
120000 67.8 337 0.27
150000 80.1 399 0.24
180000 90.0 457 0.20
 
6300KVA~63000KVA three-phase three-windings NLTC power transformer
Rated capacity
(KVA)
Voltage combination and range of tapping  Vector
group
No-load loss kw(9) Load loss kw(9) No-load current Short circuit
impedance
High voltage Medium voltage Low voltage Step up  Step down
6300 110±2×2.5%
115±2×2.5%
121±2×2.5%
35
37
38.5
6.3
6.6
10.5
21
YNyn0d11 8.90 44.0 0.66 17.5~18.5

10.5

6.5
10.5

18~19

6.5
8000 10.6 53.0 0.62
10000 12.6 63.0 0.59
12500 14.7 74.0 0.56
16000 17.9 90.0 0.53
20000 21.1 106 0.53
25000 24.6 126 0.48
31500 29.4 149 0.48
40000 34.8 179 0.44
50000 41.6 213 0.44
63000 49.2 256 0.40
 
6300KVA~63000KVA three-phase two windings OLTC power transformer
Rated capacity
(KVA)
Voltage combination and range of tapping  Vector
group
No-load loss kw(9) Load loss kw(9) No-load current Short circuit
impedance
High voltage Low voltage
6300 110±8×2.5% 6.3
6.6
10.5
21
YNd11 8.00 35.0 0.64 10.5
8000 9.60 42.0 0.64
10000 11.3 50.0 0.59
12500 13.4 59.0 0.59
16000 16.1 73.0 0.55
20000 19.2 88.0 0.55
25000 22.7 104 0.51
31500 27.0 123 0.51
40000 32.3 156 0.46 12~18
50000 38.2 194 0.46
63000 45.4 232 0.42
 
6300KVA~63000KVA three-phase three-windings OLTC power transformer
Rated capacity
(KVA)
Voltage combination and range of tapping  Vector
group
No-load loss kw(9) Load loss kw(9) No-load current Short circuit
impedance

 
High voltage Medium voltage Low voltage
6300 110±8×2.5%
 
36
37
38.5
6.3
6.6
10.5
21
YNyn0d11 9.60 44.0 0.76

10.5



18~19


6.5
8000 11.5 53.0 0.76
10000 13.6 62.0 0.71
12500 16.1 74.0 0.71
16000 19.3 90.0 0.67
20000 22.8 106 0.67
25000 27.0 126 0.62
31500 32.1 149 0.62
40000 38.5 179 0.58
50000 45.5 213 0.58
63000 54.1 256 0.53

 6300KVA~63000KVA three-phase two windings low voltage 35KV NLTC power transformer
Rated capacity
(KVA)
Voltage combination and range of tapping  Vector
group
No-load loss kw(9) Load loss kw(9) No-load current Short circuit
impedance
High voltage Low voltage
6300 110±2×2.5%
115±2×2.5%
121±2×2.5%
36
37
38.5
YNd11 8.00 37.0 0.67 10.5
8000 9.60 44.0 0.67
10000 11.2 52.0 0.65
12500 13.1 62.0 0.65
16000 15.6 76.0 0.57
20000 18.5 94.0 0.57
25000 21.9 110 0.53
31500 25.9 133 0.53
40000 30.8 155 0.49
50000 36.9 193 0.49
63000 43.6 232 0.45
Note: We can manufacture the product out of the volume mentioned in the table per
consumer's requiremnt and its performance parameters are settled referred to requirement.


110kv Level Three-Phase on-Load Tap-Changing Electric Power Transformer







 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
85
Year of Establishment
1996-01-16